BE1-11 Protection System
BE1-11  

 

 

 

 

 

BE1-11

  BE1-11

 

BE1-11   BE1-11   BE1-11

Also available in fully drawout half rack case (11f,11g,11i styles)

 

  • Correctly configuring protection with confidence has never been easier than with the BE1-11. The BE1-11 Protection System is designed with many features to address issues with reliability arising from the complexity of programming. With BESTspace™ files, multiple BESTlogic™Plus preprogrammed logic schemes, and associated application notes, you can be confident that you have the protection you need. The BE1-11 is available in Feeder, Generator, Intertie, Transformer, and Motor styles for multiple applications.

 

Manuals Bulletins Technical Resources

Applications

 

Benefits

Note: IEEE device functions are configured through the BE1-11 style number.

  • Entering protection settings with confidence is easy with BESTCOMSPlus® software that provides intuitive settings with graphs, built-in error checking, and summary screens.
  • Complex protection schemes are easy to configure and understand with preprogrammed schemes, drag-and-drop logic, user labels, and notes provided by BESTlogic™Plus.
  • The Offline Simulator, provided in BESTlogic™Plus, helps identify and troubleshoot the logic without the expensive need for physical hardware.
  • Adaptable coordination for difficult applications is made possible by 24 industry-standard timing curves and five user-defined curves.
  • Meet your modern communications needs with 10/100Mbit copper or 100Mbit fiber-optic Ethernet with IEC 61850, DNP, or Modbus™.
  • Connection is easy, even when using multiple large wires, with large screw terminals for all terminations.
  • Get the information you need for system analysis with distance-to-fault, oscillography, demand metering, power quality, breaker monitoring, and other data provided by the BE1-11.
  • Easily navigate settings and metering with the intuitive Human Machine Interface (HMI) menu and large LCD display.
  • Fully configurable analog outputs can be used to drive analog meters. Easily assigned trip points can be scaled by the user to reflect measured parameters.
  • Up to 14 combined alarm and trip temperature monitoring points are possible using an optional RTD module.
  • Reduce installation costs and improve reliability by mounting an optional RTD module near the point of measurement to minimize cable lengths.
  • UL Class 1, Div 2 rating allows the optional RTD module to be installed in harsh environments.